Projection
- 3″ (76mm) in undogged position
- 2-5/8″ (67mm) in dogged position
Warranty
One year on electrified, componentsLifetime on hardware components
Maximum Door Height
- 7′ (2134mm) – Standard
- 8′ (2438mm) – Optional
- 10′ (3048mm) – Optional (panic device only)
Cover
Stainless steel, zinc
Trim
- Archer, August, Charles, Johnston, Joshua, Louis, Warren, William or Withnell lever with escutcheon
- Pull plate trim (excluding 45PT)
- Rim cylinder x optional pull
Door Thickness
1-3/4″ (44mm) – Standard up to 3″, except with night latch which is 2-1/2″
Fasteners
- Wood and machine screws
- Thru-bolts
DOOR WIDTH in. – EXIT DEVICE
36
Cover Tube
Aluminum
ELECTRICS – EXITS
NOT APPLICABLE
ACCESSORIES – EXITS
NOT APPLICABLE
FINISHES – EXITS
NOT APPLICABLE
MISC. – EXITS
NOT APPLICABLE
DOOR HEIGHT in. – EXIT DEVICE
120
End Caps
- Standard end cap (zinc)
- OPTIONAL Flush end cap (zinc)
RATINGS – EXITS
STANDARD – NON-FIRE RATED
Product Overview Grade 1 Surface Vertical Rod Exit Device, Less Bottom Rod
Functions:
01 – Exit Only (device)
Applications:
Heavy Duty Commercial
Notes:
- Hole plug for head cover included standard
- Recommended to be used on appropriately reinforced doors
- A spring loaded fire bolt 2-649-0166 must be used on fire-rated LBR devices used on a pair of doors to ensure the device’s fire rating
Certifications:
- ANSI/BHMA A156.3-2014 Grade 1
- UL305 Listed for Panic Hardware
- UL/cUL Listed for up to 3 hours for “A” labeled doors
- UL10C Positive Pressure Rated
- UL10B Neutral Pressure Rated
- Complies with ANSI 117.1 for accessible buildings and facilities
Finishes:
- US3, US4, US10B, US 26, US26D, US32D, BLK
- Trim not available in US32D
Warranty:
Lifetime
Dogging:
- Hex key dogging standard on panic rated devices,
- Cylinder dogging available on panic rated devices – specify “CD”. 3902 Mortise cylinder with standard cam sold separately. Cylinder Length of 1-1/8″ (29mm) – 1-3/8″ (35mm) is required
Door Width:
- 36″ (914mm) field sizeable to 30″ (762mm) panic-rated door and 28″ (711mm) fire-rated door
- 48″ (1219mm) field sizeable to 36″ (914mm) panic- or fire-rated door
- Reference electrified exit device for door width specifications
Notes:
- Hole plug for head cover included standard
- Recommended to be used on appropriately reinforced doors
- A spring loaded fire bolt 2-649-0166 must be used on fire-rated LBR devices used on a pair of doors to ensure the device’s fire rating
Rod Length:
- Rods for 7′ (2134mm) door standard
- Rods for 8′ (2438mm) door optional
- Door height of 7′ (2134mm) requires 33-1/4″ (845mm) top rod length
- Door height of 8′ (2438mm) requires 45-1/4″ (1149mm) top rod length
- Extension rod kits available, 2′ (610mm) or 3′ (914mm) for doors over 7′ (2134mm)
Stile Width:
- 5-3/8″ (137mm) – Minimum stile width required for single door and 5/8″ ( 16mm) stop
- 4-7/8″ (124mm) – Minimum stile width required for double doors
- 4-7/8″ (124mm) – Minimum stile width required for double doors x rim device with double doors x rim device with double door strike
- All stile widths are measured from door edge
Strikes:
- Stainless steel with plated rollers – Included standard with panic devices
- Solid stainless steel – Included standard with fire-rated devices
- Surface applied to frame with slotted holes for easy adjustment
- Double door strike for use with surface vertical rod and rim device available